High Temperature Industrial TV for Blast Furnace Charge Surface

XZ-LD-III Blast Furnace Charge Surface High Temperature Industrial TV is a special closed-circuit TV equipment used in high temperature environment. It is an industrial TV system specially used to monitor the distribution of materials in the blast furnace. It is an important equipment for monitoring and observing the working conditions in the blast furnace. It plays an extremely important role in improving output, reducing energy consumption and implementing safe production. It not only ensures production safety and improves product quality, but also improves working environment and reduces labor intensity, and is also convenient for centralized scheduling and automation of production process.

  XZ-LD-III Blast Furnace Charge Surface High Temperature Industrial TV is a special closed-circuit TV equipment used in high temperature environment. It is an industrial TV system specially used to monitor the distribution of materials in the blast furnace. It is an important equipment for monitoring and observing the working conditions in the blast furnace. It plays an extremely important role in improving output, reducing energy consumption and implementing safe production. It not only ensures production safety and improves product quality, but also improves working environment and reduces labor intensity, and is also convenient for centralized scheduling and automation of production process. Scope of use: The equipment can be extended into the furnace to observe the operation of various workpieces in the furnace, material melting, combustion flame, etc. Widely used in metallurgy, electric power, glass, building materials and other industries.Names: Blast Furnace Top High Temperature TV, Blast Furnace Burden Surface Sensing Infrared Camera, Blast Furnace Burden Surface Sensing Infrared Imaging System, Blast Furnace Burden Surface Sensing Infrared Temperature Measurement System.

Performance and indicators:

   Service conditions: furnace temperature ≤ 1500 ℃

Gas supply: compressed air or nitrogen, inlet pipe diameter: G1/2

Water supply: Industrial circulating water, inlet diameter G1/2 "

Gas supply requirements: pressure > 0.2 ~ 0.7 MPa,

Flow rate: 0.1 ~ 0.4 m³/min,

Compressed air inlet temperature:≤40°C

Technical parameters of infrared high temperature camera:

Operating voltage: 100V~240VAV

Lens: Special high temperature and corrosion-resistant pinhole imager. Angle of view (diagonal): 

F2.8 Field of view diagonal: 110 °, 

F3.5 Field of view diagonal: 81 °